[Solved] Fixing High Urea Temperature & Leakage Test Failure: 19748 Error Code

Tractor Error Code19748 Error Code
DescriptionEmergency shut off due to high UREA temperature in pump module or failed leakage test. Error code P2043 indicates out of range temperature sensor in pump module.

Tractor error code 19748 indicates a problem with the UREA temperature in the pump module or a failed leakage test. This error is caused by an over-temperature detection in the UREA temperature of the pump module or an out-of-range temperature sensor of the pump module. The symptoms of this error include an emergency shut off and a P2043 reagent error.

The importance of repairing this error is high as it can cause damage to the tractor’s engine.

The difficulty of repairing this error is moderate, and it requires a skilled technician to fix it. Possible fixes include replacing the temperature sensor or repairing the pump module.

Tractor error code 19748 indicates high urea temperature in the pump module or a failed leakage test, resulting in an emergency shut off. Symptoms include over-temperature detection and an out-of-range temperature sensor for the pump module’s reagent.

  • The error code 19748 indicates several symptoms.
  • These include high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module.
  • Additionally, the reagent temperature sensor of the pump module is also out of range.
  • These symptoms can cause emergency shut off of the tractor.

The error code 19748 in tractors is caused by high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module.

These symptoms can lead to an emergency shut off of the tractor.

  • The error code 19748 in tractors can be caused by several factors.
  • These include high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module.
  • Additionally, the reagent temperature sensor of the pump module being out of range can also cause this error code.
  • These symptoms can lead to an emergency shut off of the tractor.

To fix error code 19748 in tractors, check for high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module. Also, ensure that the reagent temperature sensor of the pump module is within range to prevent emergency shut off.

  • To fix error code 19748 in tractors, you need to follow these steps.
  • Firstly, check the temperature of the urea pump module and ensure it is not too high.
  • Secondly, perform a leakage test and ensure it passes.
  • Thirdly, check for over-temperature detection and ensure it is not causing the error.
  • Fourthly, check the temperature sensor of the pump module and ensure it is within the range.
  • Lastly, check the reagent temperature sensor of the pump module and ensure it is within the range.
  • By following these steps, you can fix the error code 19748 and prevent an emergency shut off of the tractor.

To fix error code 19748 in tractors, you need to check the temperature of the urea pump module, perform a leakage test, check for over-temperature detection, ensure the temperature sensor of the pump module is within range, and ensure the reagent temperature sensor of the pump module is within range. Following these steps will fix the error code and prevent an emergency shut off of the tractor. The labor and cost of fixing the error code may vary depending on the severity of the issue and the brand of the tractor.

It is recommended to consult a professional mechanic for an accurate estimate.

The error code 19748 in tractors can be caused by several factors, including high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module.

Additionally, the reagent temperature sensor of the pump module being out of range can also cause this error code.

To fix this error code, you need to check the temperature of the urea pump module, perform a leakage test, check for over-temperature detection, ensure the temperature sensor of the pump module is within range, and ensure the reagent temperature sensor of the pump module is within range.

The cost of diagnosis and fixing will depend on the repair time and required tools, with most tractor repair shops charging between $75 and $150 per hour.

Tractor error code 19748 is a common issue across various tractor brands. It indicates several symptoms, including high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module. Additionally, the reagent temperature sensor of the pump module being out of range can also cause this error code.

These symptoms can lead to an emergency shut off of the tractor. The high temperature in the urea pump module can be caused by various factors, such as a malfunctioning pump or clogged filters. The failed leakage test can be due to a damaged or faulty pump, while the out-of-range temperature sensor can be caused by a damaged sensor or wiring issues. Over-temperature detection can be due to a malfunctioning cooling system or a blocked exhaust system. To fix this error code, it is essential to diagnose the root cause of the symptoms.

This can involve checking the pump, filters, sensors, and wiring for any damage or faults. It may also require cleaning or replacing certain components. Regular maintenance and inspection of the tractor can help prevent this error code from occurring.

Which tractor brands commonly experience the 19748 error code, and how complex is this error code to fix?

Tractor error code 19748 is a common issue across various tractor brands, including John Deere, Case IH, and New Holland. This error code indicates several symptoms, including high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module. Additionally, the reagent temperature sensor of the pump module being out of range can also cause this error code. To fix this error code, it is essential to diagnose the root cause of the symptoms, which can involve checking the pump, filters, sensors, and wiring for any damage or faults. Regular maintenance and inspection of the tractor can help prevent this error code from occurring. The complexity of fixing this error code depends on the specific cause of the symptoms and may require cleaning or replacing certain components.

What is the typical cost of fixing high urea temperature and leakage test failure associated with the 19748 error code, including both parts and labor?

The cost of fixing high urea temperature and leakage test failure associated with the 19748 error code can vary depending on the root cause of the symptoms. It is essential to diagnose the issue first, which can involve checking the pump, filters, sensors, and wiring for any damage or faults. It may also require cleaning or replacing certain components. The cost of parts and labor can range from a few hundred to a few thousand dollars, depending on the severity of the issue and the brand of the tractor. Regular maintenance and inspection of the tractor can help prevent this error code from occurring, saving you money in the long run.

Are there any DIY fixes available for the 19748 error code, or is it necessary to take the tractor to a professional mechanic for repair?

It is recommended to take the tractor to a professional mechanic for repair when error code 19748 occurs. This error code can indicate several symptoms, including high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module. Additionally, the reagent temperature sensor of the pump module being out of range can also cause this error code. These symptoms can lead to an emergency shut off of the tractor. Diagnosing the root cause of the symptoms can involve checking the pump, filters, sensors, and wiring for any damage or faults. Regular maintenance and inspection of the tractor can help prevent this error code from occurring.

19748 error fault code explained

Tractor error code 19748 indicates high temperature in the urea pump module, failed leakage test, over-temperature detection, and out-of-range temperature sensor of the pump module. To fix it, diagnose the root cause, check the pump, filters, sensors, and wiring, and perform regular maintenance. Repair costs vary depending on the repair time and required tools.

[Solved] Low 12Vm Voltage Supply? Fix It With These Fuse Tips!

Troubleshoot tractor error code 10022: check fuse, voltage supply, and wiring. Prevent with regular maintenance. Repair cost ranges $75-$150/hr. Steps to fix inside.

[Solved] Fix Front Suspension Lock Out With 10021 Error Code Solution

Fix error code 10021 on a tractor with front suspension lockout solenoid over current by checking solenoid and wiring, replacing or repairing as necessary, clearing the code, and testing the lockout. Steps to fix inside.

[Solved] Fixing Front Suspension: 10020 Error Code Solenoid Overcurrent

Tractor error code 10020 signals front suspension piston solenoid issues, causing overheating, reduced performance, and abnormal noise. Fix it by checking the solenoid, circuit, valve, and piston. Steps to fix inside.

[Solved] Fix Overheating Engines With 1002 Error Code Solution

Tractor error code 1002 signals high engine coolant temp & hitch valve coil failure; causes include faulty parts, low coolant, or short circuit. Steps to fix inside.

[Solved] Fixing Front Suspension: 10019 Error Code Solution

Fixing tractor error code 10019 requires checking and replacing faulty parts like the solenoid coil or control module, with labor costs varying based on repair time and tools. Steps to fix inside.

[Solved] Fixing Front Suspension Pump: 10018 Error Code Solution

Fixing tractor error code 10018 requires checking the front suspension pump, inspecting the tank solenoid, and testing the electrical system. Prompt attention is crucial to prevent further damage. Steps to fix inside.