[Solved] Fixing Short Circuit Ground On Reverting Valve & Vent Valve – 19182 Error Code

Tractor Error Code19182 Error Code
DescriptionError code 57: Short circuit to ground in the electrically controlled 4-2way valve and Reductant Purge Control Valve (P20A2).

Tractor error code 19182 with the description “57 Reverting valve (4-2way valve?) electrically Short circuit to ground P20A2 Vent valve (Reductant Purge Control Valve) Short circuit low” indicates a problem with the tractor’s reductant purge control valve. This error code can cause the tractor to malfunction, leading to reduced performance and efficiency.

The cause of this error code is a short circuit to ground in the electrical system of the tractor’s 4-2way valve. Repairing this issue is of utmost importance as it can lead to further damage to the tractor’s engine and other components.

The difficulty of repairing this issue varies depending on the severity of the problem.

Possible fixes include repairing or replacing the electrical system or the reductant purge control valve.

The error code 19182 indicates a short circuit to ground in the electrically controlled 4-2way valve and the Reductant Purge Control Valve, causing malfunctioning of the tractor’s reverting valve.

  • The symptoms of tractor error code 19182 include a short circuit to ground in the electrically controlled reverting valve (4-2way valve), a short circuit low in the vent valve (Reductant Purge Control Valve), and a repeated occurrence of the short circuit low in the reverting valve (4-2way valve).
  • These symptoms can cause issues with the tractor’s reductant purge control system and may result in reduced performance or engine failure.
  • It is important to address these symptoms promptly to avoid further damage to the tractor.

Tractor error code 19182 is caused by a short circuit to ground in the electrically controlled reverting valve (4-2way valve) and a short circuit low in the vent valve (Reductant Purge Control Valve), which can result in reduced performance or engine failure if not addressed promptly.

  • The causes of tractor error code 19182 are a short circuit to ground in the electrically controlled reverting valve (4-2way valve), a short circuit low in the vent valve (Reductant Purge Control Valve), and a repeated occurrence of the short circuit low in the reverting valve (4-2way valve).
  • These causes can lead to issues with the tractor’s reductant purge control system, which can result in reduced performance or engine failure.
  • It is crucial to address these causes promptly to prevent further damage to the tractor.

To fix tractor error code 19182, the short circuit to ground in the electrically controlled reverting valve (4-2way valve) and the short circuit low in the vent valve (Reductant Purge Control Valve) need to be addressed promptly to prevent further damage to the tractor’s reductant purge control system, which can result in reduced performance or engine failure.

  • To fix tractor error code 19182, first, check the wiring and connectors of the electrically controlled reverting valve (4-2way valve) and the vent valve (Reductant Purge Control Valve).
  • If any damage or corrosion is found, repair or replace them.
  • Next, check the resistance of the reverting valve (4-2way valve) and the vent valve (Reductant Purge Control Valve) using a multimeter.
  • If the resistance is out of range, replace the faulty valve.
  • Finally, clear the error code using a diagnostic tool and test the tractor to ensure the issue is resolved.

To fix tractor error code 19182, check the wiring and connectors of the electrically controlled reverting valve and the vent valve for damage or corrosion. Repair or replace them if necessary.

Then, check the resistance of the valves using a multimeter and replace any faulty valves. Finally, clear the error code using a diagnostic tool and test the tractor to ensure the issue is resolved.

Tractor error code 19182 is caused by a short circuit to ground in the electrically controlled reverting valve (4-2way valve) and a short circuit low in the vent valve (Reductant Purge Control Valve). These issues can lead to problems with the tractor’s reductant purge control system, resulting in reduced performance or engine failure. To fix the issue, the wiring and connectors of the valves should be checked for damage or corrosion and repaired or replaced if necessary.

The resistance of the valves should also be checked using a multimeter, and any faulty valves should be replaced.

The cost of diagnosis and fixing will depend on the repair time and required tools, with most tractor repair shops charging between $75 and $150 per hour.

It is important to address the issue promptly to prevent further damage to the tractor.

Tractor error code 19182 is a common issue that affects many tractor brands. The symptoms of this error code include a short circuit to ground in the electrically controlled reverting valve (4-2way valve) and a short circuit low in the vent valve (Reductant Purge Control Valve). These symptoms can cause problems with the tractor’s reductant purge control system, leading to reduced performance or engine failure. It is important to address these symptoms promptly to avoid further damage to the tractor.

The causes of tractor error code 19182 are a short circuit to ground in the electrically controlled reverting valve (4-2way valve) and a short circuit low in the vent valve (Reductant Purge Control Valve).

These causes can lead to issues with the tractor’s reductant purge control system, which can result in reduced performance or engine failure. To prevent further damage to the tractor, it is crucial to address these causes promptly. If you encounter this error code, it is recommended that you seek the assistance of a qualified technician who can diagnose and repair the issue. By taking prompt action, you can ensure that your tractor continues to operate at peak performance and avoid costly repairs down the line.

Which tractor brands commonly experience the 19182 error code, and how complex is this error code to fix?

Tractor error code 19182 is a common issue that affects many tractor brands, including John Deere, Case IH, and New Holland. The symptoms of this error code include a short circuit to ground in the electrically controlled reverting valve (4-2way valve) and a short circuit low in the vent valve (Reductant Purge Control Valve). These symptoms can cause problems with the tractor’s reductant purge control system, leading to reduced performance or engine failure. The causes of this error code are complex and require the assistance of a qualified technician to diagnose and repair the issue. It is crucial to address these causes promptly to prevent further damage to the tractor and ensure it continues to operate at peak performance.

What is the typical cost of fixing a short circuit ground on the reverting valve and vent valve for the 19182 error code, and how much labor is involved?

The cost of fixing a short circuit ground on the reverting valve and vent valve for the 19182 error code can vary depending on the tractor brand and the severity of the issue. It is recommended to seek the assistance of a qualified technician who can diagnose and repair the issue. The labor involved can also vary depending on the complexity of the repair. It is important to address these symptoms promptly to avoid further damage to the tractor’s reductant purge control system, which can result in reduced performance or engine failure. By taking prompt action, you can ensure that your tractor continues to operate at peak performance and avoid costly repairs down the line.

Are there any DIY fixes for the 19182 error code, or is it necessary to take the tractor to a professional mechanic for repair?

Tractor error code 19182 can cause issues with the reductant purge control system, leading to reduced performance or engine failure. The symptoms of this error code include a short circuit to ground in the electrically controlled reverting valve (4-2way valve) and a short circuit low in the vent valve (Reductant Purge Control Valve). The causes of this error code are also related to these valves. It is important to address these symptoms promptly to avoid further damage to the tractor. It is recommended to seek the assistance of a qualified technician who can diagnose and repair the issue. DIY fixes are not recommended for this error code.

19182 error fault code explained

Tractor error code 19182 indicates a short circuit in the electrically controlled reverting valve and vent valve, leading to issues with the reductant purge control system.

To fix the issue, check the wiring and connectors, test the resistance of the valves, and replace any faulty valves.

Seek the assistance of a qualified technician to prevent further damage.

[Solved] Fixing Tractor Error Code 529: Output B Driver Shorted High Or Open

When faced with tractor error code 529, act swiftly to avoid further damage by addressing the issue promptly. Check wiring, inspect Output B driver circuit, replace if needed, and assess fuse, sensor, and ECM for faults. Seek professional help if required. Steps to fix inside.

[Solved] Fixing Tractor Error Code 5282: Solving The Loader Auxiliary Valve Supply Short

To resolve error code 5282, check solenoid for damage, inspect wiring and connectors, test control module, replace blown fuses, address specific cause, repair or replace faulty components, test functionality, and monitor for issues. Steps to fix inside.

[Solved] Fixing Tractor Error Code 5281: Solving The Open Circuit Supply Issue

Error code 5281 indicates an open circuit in the forward solenoid of the loader auxiliary valve. Check and replace faulty components, repair broken wires, and ensure proper power supply and hydraulic system functionality. Steps to fix inside.

[Solved] Fixing Error Code 5273: Solving The Open Circuit Red In Loader Bucket Valve Solenoids

The error code 5273 points to a problem with the ALL Loader Bucket Valve (Directional) Solenoids Return Open Circuit Red. Seek professional help if needed. Steps to fix inside.

[Solved] Fixing Error Code 5272: Loader Bucket Valve Shorted To Ground Red

Error code 5272 points to a problem with the loader bucket valve and solenoid(s) being shorted to ground. Check wiring, connections, and components for damage, and repair or replace as needed. Steps to fix inside.

[Solved] Fixing Error Code 5271: Loader Bucket Valve Shorted To Power Red

The error code 5271 points to a short circuit between the loader bucket valve and solenoid(s), causing unresponsiveness and erratic behavior. Disconnect power, inspect and repair wiring, and test the bucket. If problem persists, consult a technician. Steps to fix inside.